sa1dl4sm-rev0611
Copyright 2011 Warren Rupp, Inc. All rights reserved.
Table of Contents
Engineering Data, Temperature Limitations, & Performance Curve ...................... 1
Explanation of Pump Nomenclature ...................................................................... 2
Dimensions ............................................................................................................ 3
Principle of Operation ............................................................................................ 4
Installation and Start-Up ........................................................................................ 4
Chamber Porting ................................................................................................... 4
Air Supply .............................................................................................................. 5
Air Inlet & Priming .................................................................................................. 5
Air Exhaust ............................................................................................................ 5
Between Uses ....................................................................................................... 5
Check Valve Servicing ........................................................................................... 5
Diaphragm Servicing ............................................................................................. 5
Air Valve Lubrication .............................................................................................. 6
ESADS+Plus
®
:
Externally Serviceable Air Distribution System ................................ 6
Pilot Valve .............................................................................................................. 7
Pilot Valve Actuator ................................................................................................ 7
Service Instructions: Troubleshooting ................................................................... 7
Warranty ................................................................................................................ 8
Recommended Accessories .................................................................................. 8
Important Safety Information ................................................................................. 9
Recycling ............................................................................................................... 9
Grounding The Pump .......................................................................................... 10
Material Codes .................................................................................................... 11
Composite Repair Parts List ...........................................................................12-13
Composite Repair Drawing.................................................................................. 14
CE Declaration of Conformity - Machinery .......................................................... 15
CE Declaration fo Conformity - ATEX .................................................................. 16
Explanation of ATEX Certication ........................................................................ 17
SERVICE AND OPERATING MANUAL
Model SA1
Model SA25
Type 4
Warren Rupp, Inc. A Unit of IDEX Corporation • 800 N. Main St., Manseld, Ohio 44902 USA
Telephone (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
Original Instructions
II 2GD T5


Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - Model SA25

sa1dl4sm-rev0611Copyright 2011 Warren Rupp, Inc. All rights reserved.Table of ContentsEngineering Data, Temperature Limitations, & Performance Cur

Página 2 - SA25 Type 4

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 9This pump is pressurized internally with air pressure during operation. Always make certain that

Página 3 - SA1 & SA25

Model SA1, SA25 Type 4 Page 10 sa1dl4sm-rev0611 Grounding The PumpTo reduce the risk of static electrical sparking, this pump must be grounded. Che

Página 4

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 11    

Página 5

Model SA1, SA25 Type 4 Page 12 sa1dl4sm-rev0611 ITEM TOTAL NO. PART NUMBER DESCRIPTION RQD. 1 165-042-157 Cap, Valve Body (AL Center)

Página 6

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 13 ITEM TOTAL NO. PART NUMBER DESCRIPTION RQD. 38 545-004-330 Nut, Hex 2039 115-071-080

Página 7

Model SA1, SA25 Type 4 Page 14 sa1dl4sm-rev0611 SuctionDischarge61 (SS & Alloy C units only)(62)

Página 8 - SAFETY WARNING

Signature of authorized personRevision Level: EPrinted name of authorized personDavid RoseberryDate of issueOctober 20, 2005TitleEngineering ManagerDa

Página 9 - WARRANTY

In accordance with ATEX Directive 94/9/EC, Equipment intended for use in potentially explosive environments.EN 60079-25: 2004For pumps equipped with P

Página 10 - RECYCLING

EC Declaration of ConformityATEX Summary of MarkingsType Marking Listed InNon-Conductive FluidsEC Type Certificate No. Pumps: KEMA 09ATEX0071 X T

Página 11 - Grounding The Pump

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 1SA1 Type 4 SA25 Type 4 FLAP-VALVEPERFORMANCE CURVES® pumps are designed to be powered only by compr

Página 12 - MATERIAL CODES

Model SA1, SA25 Type 4 Page 2 sa1dl4sm-rev0611 SA1 & SA25Copyright© 2009 IDEX AODD, Inc. All rights reserved. Speci

Página 13 - Model SA1

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 3SA1 & SA25Copyright© 2009 IDEX AODD, Inc. All rights reserved. Specif

Página 14 - ITEM TOTAL

Model SA1, SA25 Type 4 Page 4 sa1dl4sm-rev0611 PLEASE NOTE!The photos shown in this manual are for general instruction only. Your specic model may

Página 15 - Discharge

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 5AIR SUPPLYAir supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet to an a

Página 16 - Declaration of Conformity

Model SA1, SA25 Type 4 Page 6 sa1dl4sm-rev0611 capscrew of the opposite side to keep the rod from rotating. If the opposite chamber is assembled, t

Página 17 - EC Declaration of Conformity

sa1dl4sm-rev0611 Model SA1, SA25 Type 4 Page 7Remove the spool from the sleeve. Using an arbor press or bench vise (with an improvise

Página 18

Model SA1, SA25 Type 4 Page 8 sa1dl4sm-rev0611 B. Make certain the suction line or strainer is not plugged. Restriction at the suction is indicate

Modelos relacionados SA1