WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
520-057-000 8/00 Model EB3-SM Page 1
SERVICE AND OPERATING MANUAL
Model EB3-SM
Type 3
PRINCIPLE OF OPERATION
This ball check valve pump is powered by compressed air and is a 1:1 pressure
ratio design. It alternately pressurizes the inner side of one diaphragm chamber, while
simultaneously exhausting the other inner chamber. This causes the diaphragms,
which are connected by a common rod, to move endwise. Air pressure is applied over
the entire surface of the diaphragm, while liquid is discharged from the opposite side.
The diaphragm operates under a balanced condition during the discharge stroke,
which allows the unit to be operated at discharge heads over 200 feet (61 meters) of
water head.
Since the diaphragms are connected by a common rod, secured by plates to the
center of the diaphragms, one diaphragm performs the discharge stroke, while the
other is pulled to perform the suction stroke in the opposite chamber.
For maximum diaphragm life, keep the pump as close to the liquid being pumped
as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may
require a back pressure regulating device. This will maximize diaphragm life.
Alternate pressuring and exhausting of the diaphragm chamber is performed by
means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is applied
to one diaphragm chamber and the other diaphragm chamber exhausts. When the
spool shifts to the opposite end of the valve body, the porting of chambers is reversed.
The air distribution valve spool is moved by an internal pilot valve which alternately
pressurizes one side of the air distribution valve spool, while exhausting the other side.
The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate
coming in contact with the end of the pilot valve spool. This pushes it into position for
shifting of the air distribution valve.
The chambers are manifolded together with a suction and discharge check valve
for each chamber, maintaining flow in one direction through the pump.
INSTALLATION & START-UP
Locate the pump as close to the product being pumped as possible, keeping
suction line length and number of fittings to a minimum. Do not reduce line size.
For installations of rigid piping, short flexible sections of hose should be installed
between pump and piping. This reduces vibration and strain to the piping system. A
Warren Rupp Tranquilizer
®
surge suppressor is recommended to further reduce
pulsation in flow.
This pump was tested at the factory prior to shipment and is ready for operation.
It is completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters)
or less. For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior
to priming.
AIR SUPPLY
Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet
to an air supply of sufficient capacity and pressure required for desired performance.
When the air line is solid piping, use a short length of flexible hose [not less than
3
/4"
(19mm) in diameter] between pump and piping to eliminate strain to pipes. Use of a
Warren Rupp Filter/Regulator in the air line is recommended. An air line lubricator is
not recommended, particularly if EPDM is being used. Chemical attack could occur.
AIR INLET & PRIMING
For start-up, open an air valve approximately
1
/2 to
3
/4 turn. After the unit primes,
an air valve can be opened to increase flow as desired. If opening the valve increases
cycling rate, but does not increase flow rate, cavitation has occurred, and the valve
should be closed slightly.
IMPORTANT
Read these instructions completely,
before installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to
comply with the recommendations
stated in this manual will damage the
pump, and void factory warranty.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or other
miscellaneous equipment must be
grounded.
BEFORE OPERATION
Before pump operation, inspect all
gasketed fasteners for looseness caused
by gasket creep. Retorque loose fasten-
ers to prevent leakage. Follow recom-
mended torques stated in the card at-
tached to the new pump.
DANGER
Before doing any maintenance on the
pump, be certain all pressure is com-
pletely vented from the pump, suction,
discharge, piping, and all other open-
ings and connections. Be certain the air
supply is locked out or made non-
operational, so that it cannot be started
while work is being done on the pump.
Be certain that approved eye protection
and protective clothing are worn at all
times in the vicinity of the pump. Failure
to follow these recommendations may
result in serious injury or death.
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - Model EB3-SM

WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.c

Página 2

Model EB3-SM Page 2 520-057-000 8/00For the most efficient use of compressed air and the longest diaphragm life, throttlethe air inlet to the lowest c

Página 3

520-057-000 8/00 Model EB3-SM Page 3would entail the use of an air line lubricator (available from Warren Rupp) set to deliverone drop of 10 wt., non-

Página 4 - HAZARD WARNING

Model EB3-SM Page 4 520-057-000 8/00is made by removing a retaining ring (each end) securing the end cap on the valvebody assembly. With the end caps

Página 5 - WARRANTY

© 2000 Warren Rupp, Inc. All rights reserved.® Warren Rupp, SandPIPER, and Tranquilizer are registered tradenames of Warren Rupp, Inc.® Neverseize is

Página 6

ITEM TOTALNO. PART NUMBER DESCRIPTION RQD.1 070-006-170 Bearing, Sleeve 22 114-002-156 Bracket, Intermediate 1114-002-010 Bracket, Intermediate 13 720

Página 7

MATERIAL CODESThe Last 3 Digits of Part NumberModel EB3-SM Page 7 520-057-000 8/00Repair Parts shown in bold face (darker)type are more likely to need

Página 8 - Printed in U.S.A

WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.c

Comentários a estes Manuais

Sem comentários