IMPORTANT
Read these instructions completely,
before installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to
comply with the recommendations
stated in this manual will damage the
pump, and void factory warranty.
HAZARD WARNING
POSSIBLE EXPLOSION HAZARD can
result if 1, 1, 1,-Trichloroethane,
Methylene Chloride or other
Halogenated Hydrocarbon solvents are
used in pressurized fluid systems
having Aluminum or Galvanized wetted
parts. Death, serious bodily injury and/
or property damage could result.
Consult with the factory if you have
questions concerning Halogenated
Hydrocarbon solvents.
DANGER
Before doing any maintenance on the
pump, be certain all pressure is com-
pletely vented from the pump, suction,
discharge, piping, and all other open-
ings and connections. Be certain the air
supply is locked out or made non-
operational, so that it cannot be started
while work is being done on the pump.
Be certain that approved eye protection
and protective clothing are worn at all
times in the vicinity of the pump. Failure
to follow these recommendations may
result in serious injury or death.
PRINCIPLE OF PUMP OPERATION
This ball type check valve pump is powered by compressed air and is a 1:1
pressure ratio design. It alternately pressurizes the inner side of one diaphragm
chamber, while simultaneously exhausting the other inner chamber. This causes the
diaphragms, which are connected by a common rod, to move endwise. Air pressure
is applied over the entire surface of the diaphragm, while liquid is discharged from the
opposite side. The diaphragm operates under a balanced condition during the
discharge stroke, which allows the unit to be operated at discharge heads over 200
feet (61 meters) of water head.
Since the diaphragms are connected by a common rod, secured by plates to the
center of the diaphragms, one diaphragm performs the discharge stroke, while the
other is pulled to perform the suction stroke in the opposite chamber.
For maximum diaphragm life, keep the pump as close to the liquid being pumped
as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may
require a back pressure regulating device. This will maximize diaphragm life.
Alternate pressurizing and exhausting of the diaphragm chamber is performed by
means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is applied
to one diaphragm chamber and the other diaphragm chamber exhausts. When the
spool shifts to the opposite end of the valve body, the porting of chambers is reversed.
The air distribution valve spool is moved by an internal pilot valve which alternately
pressurizes one side of the air distribution valve spool, while exhausting the other side.
The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate
coming in contact with the end of the pilot spool. This pushes it into position for shifting
of the air distribution valve.
The chambers are manifolded together with suction and discharge check valves
for each chamber, maintaining flow in one direction through the pump.
INSTALLATION & START-UP
Locate the pump as close to the product being pumped as possible, keeping
suction line length and number of fittings to a minimum. Do not reduce line size.
For installations of rigid piping, short flexible sections of hose should be installed
between pump and piping. This reduces vibration and strain to the piping system. A
Warren Rupp Tranquilizer
®
surge suppressor is recommended to further reduce
pulsation in flow.
This pump was tested at the factory prior to shipment and is ready for operation.
It is completely self-priming from a dry start for suction lifts of 10-15 feet (9.14 meters)
or less. For suction lifts exceeding 15 feet of liquid, fill the chambers with liquid prior
to priming.
AIR SUPPLY
Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet
to an air supply of sufficient capacity and pressure required for desired performance.
When the air line is solid piping, use a short length of flexible hose not less than
3
/4"
(19mm) in diameter between pump and piping to eliminate strain to pipes.
AIR INLET & PRIMING
For start-up, open an air valve approximately
1
/2 to
3
/4 turn. After the unit primes, an
air valve can be opened to increase flow as desired. If opening the valve increases
cycling rate, but does not increase flow rate, cavitation has occurred, and the valve
should be closed slightly.
For the most efficient use of compressed air and the longest diaphragm life, throttle
the air inlet to the lowest cycling rate that does not reduce flow.
WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
520-031-000 8/00 Model EB1-M Page 1
SERVICE AND OPERATING MANUAL
Model EB1-M
Type 3
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - Model EB1-M

IMPORTANTRead these instructions completely,before installation and start-up. It is theresponsibility of the purchaser to retainthis manual for refere

Página 2

WARNINGTake action to prevent static sparking.Fire or explosion can result, especiallywhen handling flammable liquids. Thepump, piping, valves, contai

Página 3

520-031-000 8/00 Model EB1-M Page 3AIR EXHAUSTIf a diaphragm fails, the pumped liquid or fumes can enter the air end of the pump,and be exhausted into

Página 4 - Printed in U.S.A

Model EB1-M Page 4 520-031-000 8/00BETWEEN USESWhen used for materials that tend to settle out or transform to solid form, the pumpshould be completel

Página 5

ITEM TOTALNO. PART NUMBER DESCRIPTION RQD.1 095-051-551 Body, Spool Valve 12 031-039-000 Sleeve & Spool Set 13 560-058-360 O-Ring 84 165-038-356 C