Batch Control/Stroke Counter Page 2Batch-sc-rev0611
520-180-000 3/02 Batch Control / Stroke Counter Page 2
Programming for Accuracy:
Batch Control Mode
Published pump performance is the starting
point for programming the batch controller.
But your actual system performance must be
verified, to achieve the expected 1 to 3% accu-
racy. This is accomplished through initial test
runs and measurement. On the following page
you will find an example showing the recom-
mended sequence for verifying your system’s
actual performance.
Batch Controller Mode
Inthismode,theControlcanbeprogrammedtotransferaxed
volumeofproduct.APresetCountisprogrammedintooneoftheten
programstorageareas(P0-P9).Thistellsthepumphowmuchproduct
willbetransferred(one“batch”)eachtimetheControlisactivated.
ThereisaSTARTswitchandaSTOPswitchmountedonthefrontof
theControlforthispurpose.Thereisalsoaninternalconnectionfor
remoteSTARTandSTOPswitchesthatacustomermaywanttoinstall.
NOTE: Use a momentary contact switch when using a remote
start/stop control.
Inthebatchcontrolmode,theTotalCountfunctionremainsactive.
Attheendofashift(severalprogrammed“batches”)thecustomercan
referencethetotalstrokecountortransferredvolumeofuidhandled
duringthetimeperiod.Allotherbasicfunctionsremainactive(Scale
Factor,ResetTotalCount),aswellasadvancedfunctions(i.e.Preset
Count, multiple program storage, Reset Preset Count) which are
explainedlaterinthismanual.
TheBatchControllerModealsousesthePulseOutputInterfaceto
receiveacountfromthepump.Itrequiresanelectricsolenoidvalve
(availablefromWarrenRupp)intheairlinetothepump.This
valveis
anormallyclosed,3-way,ACvoltage(standardcontrol)unit,andis
purchasedseparately.Thesolenoidstartsandstopsthepumpthrough
thecontrol.Thepumpisstoppedbyturningofftheairsupplytothe
pump,afterithastransferredabatch,volumeorcountprogrammed
intothecontrol.Thepumpisrestartedbyturningontheairsupplyto
thepump.
In this Mode of operation the pump will start pumping when it
receivesasignalfromthecontrol.Thisopensthevalveintheairline.
Thesignalcanbeactivatedfromthecontrolmountedswitchorfroma
remotesignal.ThepumpwillstopautomaticallyoncethePresetCount
has beenreached.The pumpcanalso bestoppedmid-operation,
usingthecontrolmountedSTOPswitchorfromaremoteSTOPsignal.
Whenrestarted,thepumpwillcontinuetheoperationfromthepoint
ofinterruption.
Ifpowertothecontrolislostduringoperation,thepumpwillstop.
Whenpowerisrestored,thecontrolresetstotheP0program.The
pumpwillnotcontinueoperationwithoutreceivingaSTARTsignal.This
functionistopreventaccidentsorproductspillage.Beforere-starting
theunit,be
certaintoselecttheprogramwhichwasinterrupted.When
thepumphascompletedacycle,thePresetCountdisplaywillash
untilitisactivatedagain.Whenreactivated,thedisplaywillresetand
restartthecountfromthePresetCountselected.Ifthecountisstopped
mid-cyclefromtheSTOPswitch,thedisplaywillnotush.
When viewing the PRESET COUNT, a flashing LED display means
the pump was stopped after COMPLETING the programmed
cycle.
If the STOP button is used to stop the operation mid-cycle, the
display will not flash. When reactivated, the pump will continue
the cycle from the point of interruption.