SERVICE & OPERATING MANUAL
Model S1F Non-Metallic Design Level 2
Engineering Data and Temperature Limitations ...................................................................... 1
Explanation of Pump Nomenclature ........................................................................................ 2
Performance Curve, Model S1F Non-Metallic Design Level 2 ............................................... 3
Dimensions: S1F Non-Metallic ................................................................................................. 4
Metric Dimensions: S1F Non-Metallic ..................................................................................... 5
Dimensions: S1F Non-Metallic with Spill Prevention ................................................................ 6
Metric Dimensions: S1F Non-Metallic with Spill Prevention .................................................... 7
Principle of Pump Operation .................................................................................................... 8
Installation and Start-up ........................................................................................................... 8
Air Supply ................................................................................................................................. 8
Air Valve Lubrication ................................................................................................................. 8
Air Line Moisture ...................................................................................................................... 8
Air Inlet and Priming ................................................................................................................. 8
Between Uses .......................................................................................................................... 8
Installation Guide ...................................................................................................................... 9
Important Safety Information ................................................................................................. 10
Material Codes ....................................................................................................................... 10
Troubleshooting ...................................................................................................................... 11
Warranty ................................................................................................................................. 11
Composite Repair Parts Drawing .......................................................................................... 12
Overlay Option Drawing ........................................................................................................ 1 2
Composite Repair Parts List .................................................................................................. 13
RuppGUARD™ Spill Prevention Option for Virgin PTFE Equipped Pumps ......................... 14
RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 14
RuppGUARD™ Spill Prevention Concept............................................................................. 15
RuppGUARD™ Spill Prevention Option Diaphragm Servicing ............................................ 15
Filling RuppGUARD™ Chambers with Liquid ....................................................................... 15
RuppGUARD™ Spill Prevention Option for TPE Equipped Pumps ..................................... 16
RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 16
RuppGUARD™ Spill Prevention Concept with TPE Diaphragms ........................................ 17
RuppGUARD™ Spill Prevention Option with TPE Diaphragm ............................................. 17
Air Distribution Valve Assembly Drawing ............................................................................... 18
Main Air Valve Assembly Parts List ....................................................................................... 18
Air Distribution Valve Servicing .............................................................................................. 19
Air Distribution Valve with Stroke Indicator Options .............................................................. 20
Air Distribution Valve with Stroke Indicator Parts List ........................................................... 20
Air Distribution Valve with Stroke Indicator Servicing ........................................................... 21
Pilot Valve Assembly Drawing ................................................................................................ 22
Pilot Valve Assembly Parts List.............................................................................................. 22
Pilot Valve Servicing ............................................................................................................... 23
Diaphragm Service Drawing, Non-Overlay .......................................................................... 24
Diaphragm Service Drawing, with Overlay ........................................................................... 24
Diaphragm Servicing .............................................................................................................. 25
Overlay Diaphragm Service .................................................................................................. 25
Pumping Hazardous Liquids .................................................................................................. 26
Converting the pump for piping the exhaust air .................................................................... 26
Exhaust Conversion Drawing ................................................................................................ 26
Converted Exhaust Illustration .............................................................................................. 26
Modular Check Valve Servicing ............................................................................................. 27
Modular Check Valve Drawing............................................................................................... 27
Dual Port Option Drawing ...................................................................................................... 28
Dual Porting Options .............................................................................................................. 29
Dual porting of both suction and discharge ends of the pump ............................................. 29
Single porting of the suction and dual porting of the pump discharge.................................. 29
Dual porting of the suction and single porting of the pump discharge ................................. 29
Leak Detection Options Drawing........................................................................................... 30
RuppTech® Electronic Leak Detector Installation ................................................................ 30
Mechanical Leak Detector Installation .................................................................................. 30
RuppTech® Pulse Output Kit Drawing .................................................................................. 31
RuppTech® Pulse Output Kit Option ..................................................................................... 31
Exhaust Port or Auxiliary Muffler Setup ................................................................................. 31
Integral Muffler Setup ............................................................................................................. 31
Table of Contents
CE
U.S. Patent #
400,210
5,996,627
Vista de página 0
1 2 3 4 5 6 ... 32 33

Resumo do Conteúdo

Página 1 - Table of Contents

WARREN RUPP®, INC. • A Unit of IDEX Corporation • P.O. Box 1568, Mansfield, Ohio 44901-1568 USA • Telephone (419) 524-8388 • Fax (419) 522-786

Página 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 8PRINCIPLE OF PUMP OPERATIONThis ball typ

Página 3 - S1F Non-Metallic

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 912341234Surge Suppressor020-050-000 Filt

Página 4

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 10MATERIAL CODESThe Last 3 Digits of Part

Página 5 - Design Level 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 11TROUBLESHOOTINGPossible Symptoms:• Pump

Página 6 - Dimensions: S1F Non-Metallic

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 12Overlay Option DrawingMuffler OptionDra

Página 7

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 13Composite Repair Parts ListITEM PART NU

Página 8

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 14RuppGUARD™ Option forVirgin PTFE Equipp

Página 9 - Mesh Muffler 167mm 283mm

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 15RuppGUARD™ FOR VIRGIN PTFEEQUIPPED PUM

Página 10

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 16RuppGUARD™ Option for TPEEquipped Pumps

Página 11 - INSTALLATION GUIDE

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 17RuppGUARD™ FOR TPEEQUIPPED PUMPS CONC

Página 13 - • Pump cycle seems to produce

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 18Air Distribution Valve Assembly Drawing

Página 14 - Muffler Option

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 19AIR DISTRIBUTION VALVESERVICINGTo servi

Página 15 - Composite Repair Parts List

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 20Air Valve Assembly Drawing with Stroke

Página 16 - Pumps Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 21Read these instructionscompletely, befo

Página 17 - IMPORTANT

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 22Pilot Valve Assembly Parts ListItem Par

Página 18 - Equipped Pumps Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 23Read these instructionscompletely, befo

Página 19

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 24Diaphragm Service Drawing,Non-OverlayDi

Página 20 - S1F Design Level 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 25DIAPHRAGM SERVICINGTo service the diaph

Página 21

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 26SAFE AIREXHAUSTDISPOSALAREAPUMP INSTALL

Página 22

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 27Modular Check Valve DrawingMODULAR CHEC

Página 23

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 1Quality SystemISO9001 CertifiedEnvironme

Página 24 - Pilot Valve Assembly Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 28Dual Port Option Drawing1" ANSI ST

Página 25

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 29DUAL PORTING OPTIONSSeveral dual portin

Página 26 - Non-Overlay

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 30Leak Detection Options DrawingRuppTech®

Página 27

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 31PULSE OUTPUT KIT OPTIONThis pump can be

Página 28 - Exhaust Conversion Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 2Pump BrandS= SandPIPER II®Pump Size1F=1&

Página 29 - Modular Check Valve Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 35 (8.5)10 (17)20 (34)30 (51)45 (76.5)15

Página 30 - Dual Port Option Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 4Dimensions: S1F Non-MetallicDimensions i

Página 31

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 5Metric Dimensions: S1F Non-MetallicDimen

Página 32 - MUFFLER CAP

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 6Dimensions: S1F Non-Metallicwith RuppGua

Página 33 - Integral Muffler Setup

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 7Metric Dimensions: S1F Non-Metallicwith

Comentários a estes Manuais

Sem comentários