Sandpiper HDF25 Manual do Utilizador Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
hdf1dl2sm-rev0614
sandpi p erpu m p.c o m
Model HDF1/HDF25 • 4
Air-Operated Double Diaphragm (AODD) pumps are powered
by compressed air or nitrogen.
The main directional (air) control valve
distributes
compressed air to an air chamber, exerting uniform pressure
over the inner surface of the diaphragm
. At the same time,
the exhausting air
from behind the opposite diaphragm
is directed through the air valve assembly(s) to an exhaust
port
.
As inner chamber pressure
(P1) exceeds liquid chamber
pressure
(P2), the rod
connected diaphragms shift
together creating discharge on one side and suction on the
opposite side. The discharged and primed liquid’s directions
are controlled by the check valves (ball or ap)
orientation.
The pump primes as a result of the suction stroke. The
suction stroke lowers the chamber pressure
(P3) increasing
the chamber volume. This results in a pressure differential
necessary for atmospheric pressure
(P4) to push the uid
through the suction piping and across the suction side check
valve and into the outer uid chamber
.
Suction (side) stroking also initiates the reciprocating
(shifting, stroking or cycling) action of the pump. The suction
diaphragm’s movement is mechanically pulled through its
stroke. The diaphragm’s inner plate makes contact with an
actuator plunger aligned to shift the pilot signaling valve.
Once actuated, the pilot valve sends a pressure signal to the
opposite end of the main directional air valve, redirecting the
compressed air to the opposite inner chamber.
Principle of Pump Operation
Air Line
Discharged
Fluid
Discharge
Stroke
Suction
Stroke
Primed
Fluid
2.57
65
6.89
175
"D"
16.73
425
15.59
396
DISCHARGE PORT
1" FNPT (HDF1)
1" BSPT (HDF25)
AIR INLET
1/2" FNPT
14.03
356
2.38
60
"C"
.72
18
8.57
218
"A"
"B"
2.38
60
16.41
417
SUCTION PORT
1" FNPT (HDF1)
1" BSPT (HDF25)
(OPTIONAL 90
PORT ROTATION)
AIR EXHAUST
3/4" FNPT
8.56
217
9.00
229
4X
.28 [7] MOUNTING HOLE
NOTE:
UNIT FURNISHED WITH SUB-BASE PLATE
AND RUBBER FEET AS STANDARD. FOR
STATIONARY BOLT DOWN USE, RUBBER
FEET CAN BE REMOVED.
HDF1 / HDF25
HEAVY DUTY FLAP VALVE PUMP
DIMENSIONAL TOLERANCE
1/8 [3]
[XX] = MILLIMETERS
PUMP
COFIGURATION
DIM "A" DIM "B"
DIM "C" DIM "D"
ALUMINUM
CENTER SECTION
3.95 [100] 5.86 [149] 11.12 [282] 14.55 [370]
CAST IRON
CENTER SECTION
4.10 [104] 5.54 [141] 10.80 [274] 15.75 [400]
PULSE OUTPUT
CONFIGURATION
SUCTION & DISCHARGE CONNECTIONS
HDF1
1" NPT FEMALE THREADED
CONNECTIONS
HDF25
1" BSP TAPERED FEMALE
THREADED CONNECTIONS
1" DIAMETER AIR
EXHAUST PIPING
LIQUID
LEVEL
SUCTION
LINE
MUFFLER
SUBMERGED ILLUSTRATION
Pump can be submerged if the pump materials of construction
are compatible with the liquid being pumped. The air exhaust
must be piped above the liquid level. When the pumped product
source is at a higher level than the pump (ooded suction
condition), pipe the exhaust higher than the product source to
prevent siphoning spills.
UNIVERSAL ALL AODD
2: INSTAL & OP
Vista de página 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 18 19

Comentários a estes Manuais

Sem comentários