Sandpiper Tranquilizer TA1 1/2 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Sandpiper Tranquilizer TA1 1/2. SANDPIPER Tranquilizer TA1 1/2 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513
Warren Rupp, Inc. • A Unit of IDEX Corporation • 800 N. Main St., P.O. Box 1568, Manseld, Ohio 44902-1568 USA
Telephone (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
Tranquilizer General Information .............................................................................. 1
Product Model Nomenclature ............................................................................... 2, 3
Materials and Operating Temperatures .................................................................... 3
Dimensions ........................................................................................................... 4, 5
Installation Guide ..................................................................................................... 6
Tranquilizer
®
Options ................................................................................................ 7
Grounding the Tranquilizer
®
...................................................................................... 8
Service & Operating Instructions .............................................................................. 9
Safety Information .................................................................................................... 9
Materials Codes...................................................................................................... 10
Repair Parts List ..................................................................................................... 12
Parts Drawing ......................................................................................................... 13
CE Declaration of Conformity - Machinery ............................................................. 14
CE Declaration of Conformity - ATEX ..................................................................... 15
Explanation of ATEX Certication ........................................................................... 16
CE Declaration of Conformity - Regulation EC 1935/2004 .................................... 17
Table of Contents
Tranquilizer
®
Surge Suppressors
for Air-Driven
Diaphragm Pumps
Metallic Construction
II 2GD T5
Quality System
ISO9001 Certied
Environmental
Management System
ISO14001 Certied
See pages 15 and 16
for ATEX ratings
SERVICE & OPERATING MANUAL
Original Instructions
Vista de página 0
1 2 3 4 5 6 ... 18 19

Resumo do Conteúdo

Página 1 - Tranquilizer

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513Warren Rupp, Inc. • A Unit of IDEX Corporation • 800 N. Main St., P.O. Box 1

Página 2

tranqmsm-rev0513 Page 8 Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80One eyelet end is fastened to the surge suppressor hardware.The oth

Página 3

Model TA1½ Page 9ta15mdl1sm-rev0513Tranquilizers®Model TA1½ Metallic Constructi

Página 5 - MATERIALS

Model TA1½ Page 11ta15mdl1sm-rev0513

Página 7 - Model TA80

Model TA1½ Page 13ta15mdl1sm-rev0513©2010 Warren Rupp, Inc. All rights reserved

Página 8 - INSTALLATION GUIDE

Signature of authorized personRevision Level: FPrinted name of authorized personDavid RoseberryDate of issueOctober 20, 2005TitleEngineering ManagerDa

Página 9 - Options

In accordance with ATEX Directive 94/9/EC, Equipment intended for use in potentially explosive environments.EN 60079-25: 2004For pumps equipped with P

Página 10 - WARNING WARNING

EC Declaration of ConformityATEX Summary of MarkingsType Marking Listed InNon-Conductive FluidsEC Type Certificate No. Pumps: KEMA 09ATEX0071 X T

Página 11 - Tranquilizers

Manufacturer:Warren Rupp, Inc.®, 800 N. Main Street, P.O. Box 1568,Mansfield, Ohio, 44901-1568 USA certifies that SANDPIPER® Air-Operated Double Diaph

Página 13

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513 Page 1Tranquilizer®• Nearly surge-free flow.• Steadier pressures. •

Página 14 - Model TA1½

tranqmsm-rev0513 Page 2 Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80Tranquilizer Model TA1 Tranquilizer Model TA25Tranquilizer Model TA

Página 15 - Model TA1½

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513 Page 3H = Hytrel®I = EPDMN = NeopreneNG = Neoprene Backup/PTFE Ov

Página 16 - Declaration of Conformity

tranqmsm-rev0513 Page 4 Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA804.60 1177.75 1979.27 2353.88 9811.20 2841.12 2815.13 384FULLYEXTEND

Página 17 - EC Declaration of Conformity

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513 Page 518.20 462FULLYCLOSED15.37 39011.38 2893.19 815.69 14420.67 525FULLY

Página 18

tranqmsm-rev0513 Page 6 Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA801234TranquilizerFilter/RegulatorLubricatorAir DryerAvailable from W

Página 19

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80 tranqmsm-rev0513 Page 7AL = AluminumB = NitrileCI = Cast ironT = Virgin PTFEV = FKM (

Comentários a estes Manuais

Sem comentários